Miura M020 Test Card Reader Update & Configuration
Do not proceed with this guide on production units!
Please check the sticker on the back of your terminal. If the model name contain PROD (M020-PRODxx-xx-x) do not continue with this guide since its is for test units only! There is no requirements to load production units since they are factory loaded with Hips application.
For DEVELOPMENT / TEST Card Readers only!
This is only required for TEST Card Readers, since there are issues with Miura OS V7-5 that prevent us from updating automatically.
Once you order LIVE Card Readers, we will make sure they ship with the latest OS and MPI and - if required - USB Serial Mode enabled by default.
Installing Hips Software, OS and MPI to the Miura reader (developer/test)
Do not unzip or extract any files before uploading them to the Miura device. The Miura device expects an archive!
- First download this file M000-TESTOS-V9-3.tar.gz containing the Miura OS.
- Then download this file M000-TESTOSUPDATE-V1-8.tar.gz containing the Updater Script for the Miura OS.
Install the OS
- Connect M020 to the PC/MAC with USB. A new drive called "MIURA" should appear as a USB device.
- Copy the two files M000-TESTOS-V9-3.tar.gz and M000-TESTOSUPDATE-V1-8.tar.gz to the "MIURA" drive.
- Eject the "MIURA" drive and disconnect the USB cable.
- Wait for around 10 seconds, then the Card Reader will update itself to OS V9-3.
- Wait until the terminal boots back up before you continue to "Install the MPI"
Download the MPI & Config
- Download this file M000-TESTMPI-V1-58.tar.gz containing the Miura MPI.
- Then download this file M000-TESTMPI-Vx-x-CONF100-V1.tar.gz containing the Configuration for the Miura MPI.
Install the MPI
- Connect M020 to the PC/MAC with USB. A new drive called "MIURA" should appear as a USB device..
- Copy the two files M000-TESTMPI-V1-58.tar.gz and M000-TESTMPI-Vx-x-CONF100-V1.tar.gz to the "MIURA" drive.
- Eject the "MIURA" drive and disconnect the USB cable.
- Wait for around 10 seconds, then the Card Reader will update itself to MPI V1-58.
Ready for app development.
- Now you have prepared your Miura device for app development. Download Hips demo app and SDK for iOS or SDK and demo app for Android.
- Profit
💳 In need of test cards?
Please order your test cards in Hips Webshop
Post setup instructions
- Now you need to activate the terminal in the SDK / Hips Merchant App
- Then go into Hips Merchant App or SDK and choose "Inject Keys" to remote inject the DUKPT keys.
- Lastly you need to make sure the terminal is up to date by clicking "Check updates" in the SDK UI or in Hips Merchant App.
Updated almost 4 years ago