Miura M020 Test Card Reader Update & Configuration

580

❗️

Do not proceed with this guide on production units!

Please check the sticker on the back of your terminal. If the model name contain PROD (M020-PRODxx-xx-x) do not continue with this guide since its is for test units only! There is no requirements to load production units since they are factory loaded with Hips application.

📘

For DEVELOPMENT / TEST Card Readers only!

This is only required for TEST Card Readers, since there are issues with Miura OS V7-5 that prevent us from updating automatically.

Once you order LIVE Card Readers, we will make sure they ship with the latest OS and MPI and - if required - USB Serial Mode enabled by default.

Installing Hips Software, OS and MPI to the Miura reader (developer/test)

❗️

Do not unzip or extract any files before uploading them to the Miura device. The Miura device expects an archive!

  1. First download this file M000-TESTOS-V9-3.tar.gz containing the Miura OS.
  2. Then download this file M000-TESTOSUPDATE-V1-8.tar.gz containing the Updater Script for the Miura OS.

Install the OS

  1. Connect M020 to the PC/MAC with USB. A new drive called "MIURA" should appear as a USB device.
  2. Copy the two files M000-TESTOS-V9-3.tar.gz and M000-TESTOSUPDATE-V1-8.tar.gz to the "MIURA" drive.
  3. Eject the "MIURA" drive and disconnect the USB cable.
  4. Wait for around 10 seconds, then the Card Reader will update itself to OS V9-3.
  5. Wait until the terminal boots back up before you continue to "Install the MPI"

Download the MPI & Config

  1. Download this file M000-TESTMPI-V1-58.tar.gz containing the Miura MPI.
  2. Then download this file M000-TESTMPI-Vx-x-CONF100-V1.tar.gz containing the Configuration for the Miura MPI.

Install the MPI

  1. Connect M020 to the PC/MAC with USB. A new drive called "MIURA" should appear as a USB device..
  2. Copy the two files M000-TESTMPI-V1-58.tar.gz and M000-TESTMPI-Vx-x-CONF100-V1.tar.gz to the "MIURA" drive.
  3. Eject the "MIURA" drive and disconnect the USB cable.
  4. Wait for around 10 seconds, then the Card Reader will update itself to MPI V1-58.

Ready for app development.

  1. Now you have prepared your Miura device for app development. Download Hips demo app and SDK for iOS or SDK and demo app for Android.
  2. Profit

👍

💳 In need of test cards?

Please order your test cards in Hips Webshop

Post setup instructions

  1. Now you need to activate the terminal in the SDK / Hips Merchant App
  2. Then go into Hips Merchant App or SDK and choose "Inject Keys" to remote inject the DUKPT keys.
  3. Lastly you need to make sure the terminal is up to date by clicking "Check updates" in the SDK UI or in Hips Merchant App.